Infusion Pump Portable Electric Medical Machine Pump Technical Specification:Infusion rate rangeAdjustable drop rate range: 1 /min~400 drops/min (step: 1 drop /min)Adjustable flow rate range: 1ml/h~1200ml/h(step 0.1ml/h)Purge rate: 800ml/hKVO rate: 1ml/h (1~300ml/h)3ml/h (greater than 300ml/h)Infusion volume range: 1ml

Featured Products

Infusion Pump Portable Electric Medical Machine Pump
 

Infusion Pump Portable Electric Medical Machine Pump
Infusion Pump Portable Electric Medical Machine Pump
Infusion Pump Portable Electric Medical Machine Pump

Technical Specification:

Infusion rate range
Adjustable drop rate range: 1 /min~400 drops/min 
(step: 1 drop /min)
Adjustable flow rate range: 1ml/h~1200ml/h
(step 0.1ml/h)
Purge rate: 800ml/h
KVO rate: 1ml/h (1~300ml/h)
3ml/h (greater than 300ml/h)
Infusion volume range: 1ml~9999.9ml (step: 0.1 ml)
Maximum accumulated volume: 9999.9ml (step: 0.1 ml)
Infusion Time range: 1min~9999min (step: 1 min)

Infusion accuracy: Within ±3% (using calibrated high quality IV set)
Mechanical precision: within ±2%

Occlusion alarm threshold:
High: 800 mmHg ± 200 mmHg (106.7kPa±26.7kPa)
Medium: 500 mmHg ± 100 mmHg (66.7kPa±13.3kPa)
Low: 300 mmHg ± 100 mmHg (40.7kPa±13.3kPa)
Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.

 

NIBP Range
Average deviation: ≤ ±5mmHg
Standard deviation: ≤ 8mmHg
Adult
SYS: 40mmHg~280mmHg
MEAN: 20mmHg~240mmHg
DIA: 10mmHg~220mmHg
Pediatric
SYS: 40mmHg~220mmHg
MEAN: 20mmHg~170mmHg
DIA: 10mmHg~160mmHg
Neonate
SYS: 40mmHg~135mmHg
MEAN: 20mmHg~110mmHg
DIA: 10mmHg~100mmHg
Static pressure
Range: 0mmHg~300mmHg
Deviation: 3mmHg

Resolution: 1mmHg

NIBP measurement mode
Manual
Cycle (automatic): 
Optional interval: 1min, 2min, 3min,4min, 5min, 10min, 
15min, 30min, 60min, 90min
Fast: continuous NIBP measurement, interval is 5min

NIBP alarm
High pressure alarm: >90mmHg-160mmHg
Low pressure alarm: <50mmHg-90mmHg
Accuracy: ±5%

Overpressure protection
Adult: 280 mmHg ±10 mmHg
Pediatric: 237 mmHg ±3 mmHg
Neonate: 147 mmHg ±3 mmHg

 

SpO2
Range: 0%~100%
Resolution: 1%
Accuracy: 70% to 100%, precision is 2%
0% to 69%, undefined

SpO2 alarm
Upper limit: 100%
Lower limit: 90%
Alarm value accuracy: 3%
Alarm time accuracy: 2s

Pulse rate
Range: 20bpm~300bpm
Resolution: 1bpm
Accuracy: 3bpm