Dual Channel Automatic Syringe Pump with CE Certification

Product Information:hospital Surgical Instruments Syringe Infusion Pump medical equipment (SLV-S820)Features:1. HD LCD Display, high capacity words, friendly user interface, dynamically displayworking status;2. Audible and visual alarm for There are bubbles,Tube is blocked,Close the door,IV setMismatched , Battery running out ,

Featured Products

Product Information:hospital Surgical Instruments Syringe Infusion Pump medical equipment (SLV-S820)
Features:
1. HD LCD Display, high capacity words, friendly user interface, dynamically display
working status;
2. Audible and visual alarm for There are bubbles,Tube is blocked,Close the door,IV set
Mismatched , Battery running out , Infusion finish , Equipment failure , Abnormally
Operation,Software Exception,Low battery,forget the operations etc;
3. Compatible with any brands of infusion sets after correct calibration;
4. Preset solution volume to greatly reduce the workload of nurses;
5. Work mode: ml/h and drop/min can switch freely;
6. Three levels of occlusion: high, middle and low;
7. Purge function;
8. KVO (keep-vein-open) automatically opens as infusion is completed, KVO rate is
1ml/h---5ml/h (1ml/h step);
9.Power Source:100-240Vac, 50/60Hz; Internal rechargeable Li battery,
capacity≥1,800mAh, voltage=11.1V, 4 hours backup time at the rate of 25ml/h (appointed
medium rate in IEC60601-2-24) for the new battery charged for 12hours;
10. Automatically record the settings of last infusion;

Automatic Syringe Pump with Double Channel with Ce Approved
Automatic Syringe Pump with Double Channel with Ce Approved
Automatic Syringe Pump with Double Channel with Ce Approved
Automatic Syringe Pump with Double Channel with Ce Approved


 

Specifications

Infusion Rate

ml/h mode: 1~1200ml/h (1ml/h step)

drop/min mode: 1~266drop/min (1drop/min step)

Purge Rate

100ml/h---1200ml/h (can be calibrated)

Flow Rate Accuracy

ml/h mode: Within ±5% (after correct calibration)

drop/min mode: Within ±3% (after correct calibration)

Mechanical Precision

Within ±2%

Maximum infusion pressure

150kPa

KVO Speed

1ml/h---5ml/h (1ml/h step)   

Volume Limit

1ml---9999ml

Total Infusion Volume

0---9999.9ml

Alarm Pressure

 

 

 

High 800mmHg±200mmHg (106.7kPa±26.7kPa)

Medium 500mmHg±100mmHg (66.7kPa±13.3kPa)

Low 300mmHg±100mmHg (40.7kPa±13.3kPa)

Audible and Visible Alarms

There are bubbles, tube blocked,  door closed, IV set Mismatched, battery running out, infusion finish, equipment failure , abnormally operation, software exception, low battery, forget operations, etc.

Bubble Detector

Ultrasonic wave detector; detection sensitivity ≥25μL

Forbidden

Not support blood Infusion  

   

Transport & Storage Condition

Temperature: -20ºC~+55ºC

Relative Humidity:  ≤95%

Atmospheric Pressure: 50.10KPa---106.0KPa


Automatic Syringe Pump with Double Channel with Ce Approved
Automatic Syringe Pump with Double Channel with Ce Approved
Automatic Syringe Pump with Double Channel with Ce Approved
Automatic Syringe Pump with Double Channel with Ce Approved
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours